Action potential propagation through embryonic dorsal root ganglion cells in culture. I. Influence of the cell morphology on propagation properties

C Luscher, J Streit, R Quadroni… - Journal of …, 1994 - journals.physiology.org
C Luscher, J Streit, R Quadroni, HR Luscher
Journal of neurophysiology, 1994journals.physiology.org
1. In this and the companion paper the reliability of action potential (AP) propagation through
dorsal root ganglion (DRG) cells was investigated. Experimental data were collected from
DRG cells of embryonic rat slice cultures of the spinal cord. A field stimulation electrode was
used to elicit an AP in the axon. The propagated AP or, in case of conduction block, its
electronic residue (ER), was measured intracellularly in the soma of the DRG cell. 2. The
morphological and electrophysiological data combined with published data from voltage …
1. In this and the companion paper the reliability of action potential (AP) propagation through dorsal root ganglion (DRG) cells was investigated. Experimental data were collected from DRG cells of embryonic rat slice cultures of the spinal cord. A field stimulation electrode was used to elicit an AP in the axon. The propagated AP or, in case of conduction block, its electronic residue (ER), was measured intracellularly in the soma of the DRG cell. 2. The morphological and electrophysiological data combined with published data from voltage-clamp studies were taken to implement a compartmental computer model, which allows a precise description of the propagating AP and the channel kinetics at any point along the axon. 3. The safety factor for conduction was found to be low. Thus failures of AP invasion of the DRG cell soma could occur at sites of impedance mismatch when a hyperpolarizing current was applied, a second stimulus felt into the relative refractory period of the first, or when the axon was repetitively stimulated. 4. The ERs of the failed APs had discrete amplitude levels, suggesting that the failures were always caused at the same site along the axon. These sites of low safety factor were found to be the branch point in the unipolar DRG cell and the entrance of the stem piece into the soma in both cell types, the bipolar as well as the unipolar. 5. A systematic comparison of bipolar and unipolar DRG cells showed that the AP conduction through the latter is more reliable. For large cell bodies, the unipolar configuration is needed for save conduction. 6. Conduction through unipolar DRG cells is faster than through bipolar cells because the electrical load of the soma is masked by the high-resistive stem piece. The length of this stem piece is correlated inversely to the delay caused at the branch point, as the electrical load of the soma is more efficiently masked by a long stem piece.
American Physiological Society